Title :
Quick process troubleshooting by using advanced SEM ADC system
Author :
Hsieh, C.Y. ; Yang, C.C. ; Gao, S.C. ; Chen, Joe ; Chen, Wallas ; Chen, Henry ; Cheng, Alex
Author_Institution :
Taiwan Semicond. Manuf. Co., Hsinchu, Taiwan
Abstract :
With shrinking design rules, the latest bare wafer surface inspection tools are driving sensitivity to less than 20nm. Fabs have also improved particle control-sometimes the biggest particle size is only ~30-50nm. KLA-Tencor´s SEM Review tool uses an improved alignment system and high sensitivity optical microscope (OM) to identify ~30nm particle. The review system also provides a real-time automatic defect classification system (RT-ADC) that is designed for in-line applications, offering real-time classification of defect types. Using RT-ADC, we can do fully automated bare wafer review and EDX, improving troubleshooting cycle time by 3.4X.
Keywords :
X-ray chemical analysis; optical microscopes; scanning electron microscopy; semiconductor technology; EDX; KLA-Tencor; SEM review tool; optical microscope; real-time automatic defect classification system; size 30 nm to 50 nm; wafer surface inspection tools; Inspection; Manuals; Manufacturing; Real-time systems; Scanning electron microscopy; Sensitivity; Training; EDX; RT-ADC; SEM review; bare wafer review;