• DocumentCode
    726596
  • Title

    Control strategies for a high-performance 2×27 MVA machine test bench with multilevel IGCT converters

  • Author

    Bo Qu ; Jingkui Shi ; Hongwu She ; Jie Shen ; Schroeder, Stefan ; Zhuohui Tan ; Kunlun Chen ; Jianmei Zhang ; Yulong Li ; Fan Zhang ; Zhang, Richard

  • Author_Institution
    GE Global Res., Shanghai, China
  • fYear
    2015
  • fDate
    1-5 June 2015
  • Firstpage
    611
  • Lastpage
    616
  • Abstract
    In this paper, control strategies of a 22 MW / 27 MVA machine test bench using pumpback topology are introduced. The current loop design at extremely low pulse ratios (e.g. 600 Hz carrier frequency / 80 Hz load frequency) is developed. The system stability and dynamic response are analyzed. The challenges for high-power machine control with a sine filter and a transformer connected between the voltage-source-inverter and the machine are listed and solutions are given. Afterwards, some specific test modes are introduced as well. Finally, the control strategy is validated with the motor test at the customer site.
  • Keywords
    machine control; machine testing; power filters; power transformers; thyristors; carrier frequency; control strategies; dynamic response; frequency 600 Hz; frequency 80 Hz; integrated gate commutated thyristors; load frequency; machine control; machine test bench; motor test; multilevel IGCT converters; power 22 MW; pumpback topology; sine filter; system stability; transformer; voltage-source-inverter; Bandwidth; Control systems; Delays; Machine control; Pumps; Stability analysis; Voltage control; High Power; LCL filter; Low Carrier Ratio; Motor Control; Test Bench;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Power Electronics and ECCE Asia (ICPE-ECCE Asia), 2015 9th International Conference on
  • Conference_Location
    Seoul
  • Type

    conf

  • DOI
    10.1109/ICPE.2015.7167847
  • Filename
    7167847