• DocumentCode
    727535
  • Title

    Single-transmitter setup on nonlinear mixing to measure acoustic nonlinearity of first order

  • Author

    Melchor, J. ; Peralta, L. ; Rus, G. ; Saffari, N. ; Soto, J.

  • Author_Institution
    Dept. Struct. Mech., Univ. of Granada, Granada, Spain
  • fYear
    2015
  • fDate
    10-12 June 2015
  • Firstpage
    1
  • Lastpage
    4
  • Abstract
    In this study, the acoustic nonlinearity of water was investigated using a variation of the collinear wave mixing method. One single transducer, driven at two different frequencies fa and fb, was used to generate a third frequency component at fa - fb, fa + fb, 2fa and 2fb. Such a configuration allows to cancel out system nonlinearities since no amplification of the signal beyond 10V is needed. Perturbation solutions of nonlinear parameter in water are analytically calculated and validated with experimental measurements.
  • Keywords
    mixing; nonlinear acoustics; water; H2O; collinear wave mixing method; first order acoustic nonlinearity measurement; nonlinear mixing; perturbation solutions; single-transducer setup; single-transmitter setup; water; Area measurement; Kinematics; Lead; Transducers; Voltage control; Voltage measurement;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Ultrasonic Characterization of Bone (ESUCB), 2015 6th European Symposium on
  • Conference_Location
    Corfu
  • Type

    conf

  • DOI
    10.1109/ESUCB.2015.7169919
  • Filename
    7169919