DocumentCode :
728718
Title :
Robust hydrophone with hydrothermal PZT thick-film vibrator and titanium front layer for use in high-power ultrasound fields
Author :
Okada, Nagaya ; Takeuchi, Shinichi
Author_Institution :
R&D Div., Honda Electron. Co., Ltd., Toyohashi, Japan
fYear :
2015
fDate :
24-27 May 2015
Firstpage :
147
Lastpage :
150
Abstract :
Novel robust hydrophones were fabricated by depositing hydrothermally synthesized lead zirconate titanate polycrystalline film on the back-side surface of a titanium plate. These hydrophones were resistant to damage during the measurement of the high-intensity acoustic field formed by a high-intensity focused ultrasound transducer driven continuous wave, for driving power of up to 50 W, and to the acoustic field of an ultrasonic cleaner with generation of inertial acoustic cavitation. The sensitivity of the robust hydrophone was linear up to about 8 MPa. We confirmed the linearity of response for the hydrophone at high acoustic pressure. The fabricated robust hydrophone showed receiving sensitivity across a wide frequency range. Furthermore, we observed the output waveforms of the fabricated robust hydrophone with distortion due to non-linear propagation in water. These results indicate that our hydrophone can detect broadband acoustic signals emitted by oscillating and collapsing acoustic cavitation bubbles. However, the flat tip of the hydrophone disturbed the acoustic field, as shown by the results of sonochemiluminescence in luminol solution. This means that the setting position should be considered for measurements at higher acoustic power.
Keywords :
bubbles; cavitation; chemiluminescence; hydrophones; lead compounds; sonoluminescence; thick film devices; titanium; ultrasonic propagation; ultrasonic transducers; PZT-Ti; acoustic cavitation bubbles; acoustic power; acoustic pressure; acoustic signals; continuous wave; driving power; high-intensity acoustic field; high-intensity focused ultrasound transducer; high-power ultrasound fields; hydrothermal PZT thick-film vibrator; hydrothermally synthesized lead zirconate titanate polycrystalline film; inertial acoustic cavitation; luminol solution; nonlinear propagation; output waveforms; robust hydrophones; sonochemiluminescence; titanium front layer; titanium plate back-side surface; ultrasonic cleaner; Acoustic measurements; Acoustics; Power measurement; Robustness; Sonar equipment; Transducers; Ultrasonic imaging; high-intensity ultrasound; hydrophone; hydrothermally synthesized PZT thick-film; poly-crystalline film; robust;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Applications of Ferroelectric, International Symposium on Integrated Functionalities and Piezoelectric Force Microscopy Workshop (ISAF/ISIF/PFM), 2015 Joint IEEE International Symposium on the
Conference_Location :
Singapore
Type :
conf
DOI :
10.1109/ISAF.2015.7172691