Measurement of transfer characteristics of conducted disturbance from AC power supply port to Ethernet port considering transmission mode
Author :
Matsuhima, Tohlu ; Takaya, Kazuhiro ; Okugawa, Yuichiro ; Wada, Osami
Author_Institution :
Dept. of Electr. Eng., Kyoto Univ., Kyoto, Japan
Abstract :
Conducted disturbance from AC power supply reaches a communication cable (e.g. Ethernet cable) through a communication device (e.g. switching hub). Then it affects quality of the signal communication and/or the other communication devices because the conducted disturbance propagates along the communication cable. Transmission modes in a power supply cable or a Ethernet cable are defined in this paper. Two orthogonal transmission modes, normal mode and common mode, are defined in the power supply cable. And three modes, differential mode, primary common mode, and secondary common mode, are determined in the Ethernet cable. Additionally, a measurement system of transmission and mode conversion characteristics of the conducted disturbance considering transmission modes are constructed.
Keywords :
cables (electric); electrical faults; telecommunication cables; AC power supply port; Ethernet cable; Ethernet port; conducted disturbance; differential mode; normal mode; orthogonal transmission modes; power supply cable; primary common mode; secondary common mode; signal communication quality; transfer characteristics; transmission mode; Communication cables; Metals; Switches;