  • Abstract
    Shingled writing eliminates the writer width limitation and enables further bit aspect ratio reduction to extend the areal density growth of current perpendicular magnetic recording. The achievable track density of shingled magnetic recording (SMR) is determined by the reader width rather than the writer width. However, continuously scaling of reader width increases the reader resistance and results in higher reader noise. It would be an issue to maintain enough signal-to-noise ratio of reader. The 2-D magnetic recording (TDMR) was proposed to extend the density growth by advanced signal processing technique. In TDMR configuration, there are multiple readers to read multiple tracks simultaneously. Recently, the TDMR reader was proposed as a solution of intertrack interference cancelation, which allows to use wider reader to reproduce signals from narrow tracks. In this paper, an additional reader noise is observed when the reader was positioned to read two tracks at the same time. The formation of the reader sensor appears to be closely related to the current reader structure with hard bias magnet. This issue highlights that a solution is required to enable TDMR, probably a reader structure without hard-biased.
  • Keywords
    interference suppression; magnetic recording noise; perpendicular magnetic recording; signal processing; tunnelling magnetoresistance; 2D magnetic recording; ITI cancellation; SMR; TDMR reader; advanced signal processing technique; areal density growth; bit aspect ratio reduction; hard bias magnet; intertrack interference cancellation; multiple readers; multiple tracks; perpendicular magnetic recording; reader noise; reader resistance; reader sensor; reader structure; reader width; shingled magnetic recording; shingled writing; signal-to-noise ratio; track density; writer width limitation; Magnetic domains; Magnetic noise; Magnetic separation; Magnetic shielding; Media; Noise; 2-D magnetic recording (TDMR); inter-track interference (ITI) cancelation; reader noise; shingled magnetic recording (SMR); tunneling magnetoresistive (TMR) reader;
  • fLanguage
    English
  • Journal_Title
    Magnetics, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0018-9464
  • Type

    jour

  • DOI
    10.1109/TMAG.2014.2317782
  • Filename
    6971751