DocumentCode :
731184
Title :
Comparison between experiment and 3-dimentional electromagnetic simulation of monolithic radial transmission lines for Z-pinch
Author :
Chongyang Mao ; Xiaobing Zou ; Xinxin Wang
Author_Institution :
Dept. of Electr. Eng., Tsinghua Univ., Beijing, China
fYear :
2015
fDate :
24-28 May 2015
Firstpage :
1
Lastpage :
1
Abstract :
In the design of future Z-pinch driver, the monolithic radial transmission lines (MRTL) were used to combine the outputs of many pulse generators to Z-pinch load. In order to investigate the transmission characteristic of the MRTL with different impedance profiles, 3-dimensional electromagnetic simulation has been performed. From the results of 3-dimensional electromagnetic simulation, it was found that the maximum transmitted power efficiency of hyperbolic line is nearly same as that of exponential line. The hyperbolic line may be the best choice for Z-pinch, because it is much easier in fabrication than the exponential line.
Keywords :
pulse generators; transmission lines; 3-dimensional electromagnetic simulation; Z-pinch driver; hyperbolic line; maximum transmitted power efficiency; monolithic radial transmission lines; Electromagnetic scattering; Electromagnetics; Generators; Impedance; Load modeling; Power transmission lines; Voltage measurement;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Plasma Sciences (ICOPS), 2015 IEEE International Conference on
Conference_Location :
Antalya
Type :
conf
DOI :
10.1109/PLASMA.2015.7179667