DocumentCode
737731
Title
Comparison of Wind Power Converter Reliability With Low-Speed and Medium-Speed Permanent-Magnet Synchronous Generators
Author
Zhou, Dao ; Blaabjerg, Frede ; Franke, Toke ; Tonnes, Michael ; Lau, Mogens
Volume
62
Issue
10
fYear
2015
Firstpage
6575
Lastpage
6584
Abstract
More and more wind turbine manufacturers turn to using the full-scale power electronic converter due to the stricter grid code requirements to thoroughly decouple the generator from the grid connection. However, a commonly used type of this generator is still unclear, where the selections of the low-speed (LS; direct-drive) and medium-speed (MS; one-stage) permanent-magnet synchronous generators (PMSGs) are both promising solutions. This paper will assess and compare the reliability metrics for the machine-side converter (MSC) for those two configurations. First, a translation from the mission profile of the turbine to the current and voltage loading of each power semiconductor is achieved based on synchronous generator modeling. Afterward, a simplified approach to calculate the loss profile and the thermal profile is used to determine the most stressed power semiconductors in the converter. Finally, according to the lifetime power cycles, the lifespan can be calculated when operating in various wind classes. It is concluded that, although the LS PMSG is able to eliminate the gearbox, the lifespan of its MSC is lower than the one-stage MS generator.
Keywords
Insulated gate bipolar transistors; Stators; Synchronous generators; Wind speed; Wind turbines; Lifetime prediction; Power electronics converter; lifetime prediction; loss profile; permanent-magnet synchronous generator (PMSG); permanentmagnet synchronous generator; power electronic converter; thermal profile;
fLanguage
English
Journal_Title
Industrial Electronics, IEEE Transactions on
Publisher
ieee
ISSN
0278-0046
Type
jour
DOI
10.1109/TIE.2015.2447502
Filename
7151832
Link To Document