Title :
Fast Volume Reconstruction From Motion Corrupted Stacks of 2D Slices
Author :
Kainz, Bernhard ; Steinberger, Markus ; Wein, Wolfgang ; Kuklisova-Murgasova, Maria ; Malamateniou, Christina ; Keraudren, Kevin ; Torsney-Weir, Thomas ; Rutherford, Mary ; Aljabar, Paul ; Hajnal, Joseph V. ; Rueckert, Daniel
Author_Institution :
Dept. of Comput., Imperial Coll. London, London, UK
Abstract :
Capturing an enclosing volume of moving subjects and organs using fast individual image slice acquisition has shown promise in dealing with motion artefacts. Motion between slice acquisitions results in spatial inconsistencies that can be resolved by slice-to-volume reconstruction (SVR) methods to provide high quality 3D image data. Existing algorithms are, however, typically very slow, specialised to specific applications and rely on approximations, which impedes their potential clinical use. In this paper, we present a fast multi-GPU accelerated framework for slice-to-volume reconstruction. It is based on optimised 2D/3D registration, super-resolution with automatic outlier rejection and an additional (optional) intensity bias correction. We introduce a novel and fully automatic procedure for selecting the image stack with least motion to serve as an initial registration target. We evaluate the proposed method using artificial motion corrupted phantom data as well as clinical data, including tracked freehand ultrasound of the liver and fetal Magnetic Resonance Imaging. We achieve speed-up factors greater than 30 compared to a single CPU system and greater than 10 compared to currently available state-of-the-art multi-core CPU methods. We ensure high reconstruction accuracy by exact computation of the point-spread function for every input data point, which has not previously been possible due to computational limitations. Our framework and its implementation is scalable for available computational infrastructures and tests show a speed-up factor of 1.70 for each additional GPU. This paves the way for the online application of image based reconstruction methods during clinical examinations. The source code for the proposed approach is publicly available.
Keywords :
biomedical MRI; biomedical ultrasonics; graphics processing units; image reconstruction; liver; medical image processing; obstetrics; optical transfer function; ultrasonic imaging; 2D slices; 2D-3D registration; SVR methods; artificial motion corrupted phantom data; automatic outlier rejection; fast individual image slice acquisition; fast multiGPU accelerated framework; fast volume reconstruction; fetal magnetic resonance imaging; high quality 3D image data; high reconstruction accuracy; image based reconstruction methods; input data point; intensity bias correction; liver; motion artefacts; motion corrupted stacks; point-spread function; single CPU system; slice-volume reconstruction methods; speed-up factor; state-of-the-art multicore CPU methods; superresolution; tracked freehand ultrasound; Approximation methods; Image reconstruction; Magnetic resonance imaging; Spatial resolution; Three-dimensional displays; GPU acceleration; Motion correction; fetal imaging; freehand compound ultrasound; magnetic resonance imaging;
Journal_Title :
Medical Imaging, IEEE Transactions on
DOI :
10.1109/TMI.2015.2415453