DocumentCode :
744622
Title :
Implantable Multi-Modal Sensor to Improve Outcomes in Hydrocephalus Management
Author :
Clark, Therese Marie ; Malpas, Simon C. ; McCormick, Daniel ; Heppner, Peter ; Budgett, David M.
Author_Institution :
Auckland Bioeng. Inst., Univ. of Auckland, Auckland, New Zealand
Volume :
15
Issue :
10
fYear :
2015
Firstpage :
6027
Lastpage :
6035
Abstract :
Hydrocephalus is the single most common pediatric neurosurgical problem worldwide. Current treatment of this life-threatening disorder involves diverting excess fluid from the ventricles of the brain via a prosthetic shunt. While many hydrocephalus sufferers rely heavily on their ventriculo-distal shunt to maintain a healthy intracranial pressure, shunts carry a high risk of failure. Current methods of assessing shunt patency are performed within the hospital, and many patients and their families feel bound to remaining within close proximity of a hospital in order to receive timely medical intervention in the event of a shunt failure. There is a need for a system which can detect shunt malfunction, simply and reliably. We present a novel method of obtaining flow measurements from a piezoresistive pressure transducer. This builds on an earlier development of obtaining simultaneous temperature and pressure measurement from the single ultra-miniature solid-state transducer. The flow measurement system is capable of measurements in the range 0-35 ml/h, typical of the fluid flow rates through a hydrocephalus shunt. Within the flow range 0-14 ml/hour the resolution is 2 ml/hour. For flow rates greater than 16 ml/hour the resolution is 5 ml/hour. Employing a thermal flow sensing technique, the maximum heating of the local fluid is 0.65 ± 0.02 °C. The flow signal is independent of ambient temperature. The sensor would be implanted in the shunt to allow the detection of the flow rate of fluid through it, enabling the clinician to measure the patency of a shunt in real time.
Keywords :
biomedical measurement; biomedical transducers; brain; flow measurement; flow sensors; medical disorders; piezoresistive devices; pressure measurement; temperature measurement; brain ventricle; excess fluid divertion; flow measurement system; flow signal; fluid flow rate detection; healthy intracranial pressure; high failure risk; hydrocephalus management; hydrocephalus shunt patency measurement; implantable multimodal sensor; life-threatening disorder treatment; local fluid heating; medical intervention; pediatric neurosurgical problem; piezoresistive pressure transducer; pressure measurement; prosthetic shunt; shunt failure event; shunt malfunction detection; shunt patency assessment; single ultraminiature solid-state transducer; temperature measurement; thermal flow sensing technique; ventriculo-distal shunt; Fluid flow measurement; Fluids; Heating; Pressure measurement; Temperature measurement; Temperature sensors; CSF; Cerebrospinal fluid (CSF); Microsensors; flow rate; implantable; microsensors; multiparameter sensors; piezoresistive devices; pressure measurement; semiconductor devices; sensor; shunt; temperature measurement; thermoresistivity;
fLanguage :
English
Journal_Title :
Sensors Journal, IEEE
Publisher :
ieee
ISSN :
1530-437X
Type :
jour
DOI :
10.1109/JSEN.2015.2451655
Filename :
7145377
Link To Document :
بازگشت