Title :
An Equalizer Structure with Reduced Sampling Time Reference Sensitivity
Author :
Eriksson, Lars-Erik ; Van Den Elzen, Harrie C.
Author_Institution :
Philips Res. Labs., Eindhoven, The Netherlands
fDate :
12/1/1976 12:00:00 AM
Abstract :
In the last decade the work on linear tapped delay line equalizers has proved successful in reducing intersymbol interferenceone of the largest problems in data communication systems. An adjoining problem is the selection of a sampling time reference. An equalizer structure less sensitive to sampling time reference is studied for adaptive equalization. The equalization is simply done by means of tap coefficient adjustment. The equalizer consists of two parallel branches, each containing a transversal filter with adjustable tap coefficients. The branches are connected by a fixed filter, the transfer function of which is selected such that the equalizer can perform a sampling time reference displacement and a cancellation of intersymbol interference simultaneously. The criterion of goodness is the conventional meansquare error (including noise) between the actual output and a desired output. The equalizer is applied in two examples showing-in contrast to a conventional equalizer with the same total number of tap coefficients-the insensitivity of the minimum mean-square error (MMSE) to how the the sampling time reference is selected. Thus no extra circuits are needed for this purpose, while a mean-square error that is as low as the best that can be obtained with a conventional equalizer is adaptively maintained.
Keywords :
Adaptive equalizers; Adaptive equalizers; Circuit noise; Data communication; Delay lines; Interference cancellation; Intersymbol interference; Noise cancellation; Sampling methods; Transfer functions; Transversal filters;
Journal_Title :
Communications, IEEE Transactions on
DOI :
10.1109/TCOM.1976.1093248