Title :
Magnetic Priming at the Cathode of a Relativistic Magnetron
Author :
Hoff, Brad W. ; Gilgenbach, Ronald M. ; Jordan, N.M. ; Lau, Y.Y. ; Cruz, Edward J. ; French, David M. ; Gomez, Matthew R. ; Zier, Jacob C. ; Spencer, Thomas A. ; Price, David
Author_Institution :
Dept. of Nucl. Eng. & Radiol. Sci., Univ. of Michigan, Ann Arbor, MI
fDate :
6/1/2008 12:00:00 AM
Abstract :
Experiments have been performed in testing magnetic priming at the cathode of a relativistic magnetron to study the effects on high-power microwave performance. Magnetic priming consists of N/2 azimuthal magnetic perturbations applied to an N-cavity magnetron for rapid generation of the desired number of electron spokes for the pi-mode. Magnetic perturbations were imposed by utilizing three high-permeability nickel-iron wires embedded beneath the emission region of the cathode, spaced 120 apart. Magnetic priming was demonstrated to increase the percentage of pi-mode shots by 15% over the baseline case. Mean peak power for -mode shots was found to be higher in the magnetically primed case by almost a factor of two. Increases in mean microwave pulsewidth were also observed in the magnetically primed case when compared to the unprimed case (66-ns primed versus 50-ns unprimed). Magnetron starting current for the magnetically primed pi-mode exhibited a reduction to 69% of the unprimed baseline starting current.
Keywords :
cathodes; magnetrons; N-cavity magnetron; N/2 azimuthal magnetic perturbations; cathode; electron spokes; emission region; high-permeability nickel-iron wires; high-power microwave performance; magnetic priming; magnetron starting current; mode competition; relativistic magnetron; Cathodes; Electrons; High power microwave generation; Jacobian matrices; Laboratories; Magnets; Microwave communication; Microwave ovens; Performance evaluation; Testing; High power microwaves; magnetron; mode competition; priming; startup;
Journal_Title :
Plasma Science, IEEE Transactions on
DOI :
10.1109/TPS.2008.923732