Top-orthogonal-to-bottom-electrode (TOBE) CMUT arrays for 3-D ultrasound imaging
Author :
Sampaleanu, Alexander ; Peiyu Zhang ; Kshirsagar, Abhijeet ; Moussa, Walied ; Zemp, Roger
Author_Institution :
Univ. of Alberta, Edmonton, AB, Canada
Volume :
61
Issue :
2
fYear :
2014
fDate :
Feb-14
Firstpage :
266
Lastpage :
276
Abstract :
Two-dimensional ultrasound arrays hold great promise for 3-D imaging; however, wiring of each channel becomes impractical for large arrays or for small-footprint catheter probes for which the number of wires must be limited. Capacitive micromachined ultrasound transducers offer a promising solution for such 2-D array applications, but channel routing is still non-trivial. A top-orthogonal-to-bottom-electrode (TOBE) 2-D CMUT array architecture is presented along with row-column addressing schemes for low-channel-count 3-D ultrasound imaging. An N × N TOBE array is capable of obtaining 3-D images using only 2N channels. An interfacing scheme is presented in which transmit-receive signals are routed along rows while bias voltages are applied along columns, effectively allowing for single-element transmit/receive control. Simulations demonstrated potentially finer resolution and improved side lobe suppression over a previously published row-column-based imaging method. Laser vibrometer testing was done to measure membrane displacement in air and confirmed that single-element air-coupled actuation in transmit mode could be achieved using our proposed interfacing scheme. Acoustic testing was also performed in both transmit and receive modes to characterize the ability of the proposed interfacing scheme to achieve dominant-element transmission and reception in immersion operation. It was seen that membrane displacement in both modes was indeed largely confined to the active area.
Keywords :
displacement measurement; electrochemical electrodes; micromachining; ultrasonic imaging; ultrasonic transducers; vibration measurement; 2D CMUT array architecture; 2D array applications; 3D ultrasound imaging; TOBE; acoustic testing; capacitive micromachined ultrasound transducers; channel routing; interfacing scheme; laser vibrometer testing; membrane displacement; row-column addressing schemes; side lobe suppression; single-element air-coupled actuation; single-element transmit-receive control; small-footprint catheter probes; top-orthogonal-to-bottom-electrode; transmit-receive signals; two-dimensional ultrasound arrays; Crosstalk; Electrodes; Fabrication; Focusing; Switches; Ultrasonic imaging;
fLanguage :
English
Journal_Title :
Ultrasonics, Ferroelectrics, and Frequency Control, IEEE Transactions on
Publisher :
ieee
ISSN :
0885-3010
Type :
jour
DOI :
10.1109/TUFFC.2014.6722612
Filename :
6722612
Link To Document :
بازگشت