• DocumentCode
    747446
  • Title

    A wavelet-based method of measuring fluctuating harmonics for determining the filter time constant of IEC standard harmonic analyzers

  • Author

    Clarkson, Paul ; Wright, Paul S.

  • Author_Institution
    Div. of Enabling Metrol., Nat. Phys. Lab., Teddington, UK
  • Volume
    54
  • Issue
    2
  • fYear
    2005
  • fDate
    4/1/2005 12:00:00 AM
  • Firstpage
    488
  • Lastpage
    491
  • Abstract
    Harmonic analyzers are used to test the fluctuating harmonic emissions of electrical appliances to international regulations. This paper describes a wavelet-based method of measuring level-changing harmonics (bursts) for use in the calibration of these analyzers. The method is shown to be reliable for measuring various mixtures of harmonics. The importance of calibrating harmonic analyzers under conditions of fluctuating harmonics is discussed.
  • Keywords
    IEC standards; calibration; domestic appliances; electric variables measurement; harmonic analysis; measurement standards; wavelet transforms; IEC standard; electric variables measurement; electrical appliances; electromagnetic compatibility; filter time constant; fluctuating harmonic emissions; fluctuating harmonics measurement; harmonic analysis; harmonic analyzers; international regulations; signal analysis; wavelet transforms; wavelet-based method; Calibration; Discrete Fourier transforms; Electrical products; Electromagnetic compatibility; Harmonic analysis; IEC standards; Power harmonic filters; Testing; Time measurement; Wavelet analysis; Calibration; electric variables measurement; electromagnetic compatibility (EMC); harmonic analysis; signal analysis; wavelet transforms;
  • fLanguage
    English
  • Journal_Title
    Instrumentation and Measurement, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0018-9456
  • Type

    jour

  • DOI
    10.1109/TIM.2004.843327
  • Filename