• DocumentCode
    747469
  • Title

    Shielded electronic current transformer

  • Author

    Slomovitz, Daniel ; De Souza, Heriguatí

  • Author_Institution
    UTE Lab., Montevideo, Uruguay
  • Volume
    54
  • Issue
    2
  • fYear
    2005
  • fDate
    4/1/2005 12:00:00 AM
  • Firstpage
    500
  • Lastpage
    502
  • Abstract
    A current transformer with nominal ratio 10 A to 10 mA, intended for low-frequency applications, was developed. It includes an electronic device to reduce the magnetizing current, and a continuous shield in the secondary winding (coaxial cable) in order to eliminate the effect of stray capacitances. No guard-source is connected to the shield. It is proposed in this paper to leave the cable-shield-potential floating. This leads to high-accuracy results (ratio errors and phase-displacements in the order of few parts in 106 from 50 Hz to 1 kHz).
  • Keywords
    current transformers; magnetic shielding; transformer windings; 0.01 to 10 A; cable-shield-potential floating; coaxial cable; continuous shield; electronic device; low-frequency applications; magnetizing current reduction; measuring transformer; phase displacement; power frequency; secondary winding; shielded electronic current transformer; stray capacitances; Cable shielding; Capacitance; Coaxial cables; Conductors; Current transformers; Frequency; Magnetic devices; Magnetic flux; Magnetic shielding; Resistors; Compensation; current; error; guard; measuring transformer; phase displacement; power frequency; shield;
  • fLanguage
    English
  • Journal_Title
    Instrumentation and Measurement, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0018-9456
  • Type

    jour

  • DOI
    10.1109/TIM.2005.843565
  • Filename
    1408219