• DocumentCode
    748026
  • Title

    Uncertainty evaluation of a broadband attenuation standard

  • Author

    Lee, Joo-Gwang ; Kim, Jeong-Hwan ; Park, Jeong-Il ; Kang, Ung-Taeg

  • Author_Institution
    Electromagn. Wave Group, Korea Res. Inst. of Stand. & Sci., Daejeon, South Korea
  • Volume
    54
  • Issue
    2
  • fYear
    2005
  • fDate
    4/1/2005 12:00:00 AM
  • Firstpage
    705
  • Lastpage
    708
  • Abstract
    A standard step attenuator has been developed. It comprises a build-up chain of ten steps of power ratio measurement and operates in a frequency range of 10 MHz to 18 GHz. The overall system has a dynamic range of 90 dB and an expanded uncertainty of 0.006 dB (k=2). The system is used as an attenuation standard in a series radio-frequency substitution scheme. The uncertainty factors in the attenuation measurement of 40 dB at 5 GHz are fully described. For the calibration of a typical step attenuator, the expanded uncertainties are 0.011 dB for the attenuation range up to 80 dB, including the mismatch uncertainty.
  • Keywords
    attenuation measurement; attenuators; measurement standards; measurement uncertainty; power measurement; 0.010 to 18 GHz; attenuation measurement; broadband attenuation standard; microwave attenuation; microwave measurement; mismatch uncertainty; power ratio measurement; radiofrequency substitution scheme; step attenuator; uncertainty evaluation; uncertainty factors; Attenuation measurement; Attenuators; Calibration; Dynamic range; Power measurement; Radio frequency; Standards development; Switches; Thermistors; Uncertainty; Calibration; microwave attenuation; microwave measurement; uncertainty;
  • fLanguage
    English
  • Journal_Title
    Instrumentation and Measurement, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0018-9456
  • Type

    jour

  • DOI
    10.1109/TIM.2004.843336
  • Filename
    1408269