DocumentCode :
748089
Title :
Maintenance of magnetic flux density standards on the basis of proton gyromagnetic ratio at KRISS
Author :
Park, Po Gyu ; Kim, Young Gyun ; Shifrin, V. Ya
Author_Institution :
Korea Res. Inst. of Stand. & Sci., Daejeon, South Korea
Volume :
54
Issue :
2
fYear :
2005
fDate :
4/1/2005 12:00:00 AM
Firstpage :
734
Lastpage :
737
Abstract :
The proton gyromagnetic ratio (γ´p) plays a fundamental role in achieving high accuracy in magnetic measurements. We have improved our magnetic flux density standards using the γ´p-value and related techniques developed at Korea Research Institute of Standards and Science (KRISS). The standards are used for the calibration of magnetometers and support the test of sensors and materials in the range from 20 μT to 2.5 T with (4 to 80) μT/T uncertainties (k=2).
Keywords :
calibration; gyromagnetic ratio; magnetic field measurement; magnetic flux; magnetometers; measurement standards; 0.00005 to 2.5 T; KRISS; atomic magnetic resonance; magnetic flux density standards; magnetic measurements; magnetometers calibration; measurement accuracy; nuclear magnetic resonance; proton gyromagnetic ratio; sensor test; Calibration; Gyromagnetism; Magnetic flux density; Magnetic materials; Magnetic sensors; Magnetic variables measurement; Magnetometers; Materials testing; Protons; Standards development; Atomic magnetic resonance; magnetic flux density; nuclear magnetic resonance (NMR); proton gyromagnetic ratio;
fLanguage :
English
Journal_Title :
Instrumentation and Measurement, IEEE Transactions on
Publisher :
ieee
ISSN :
0018-9456
Type :
jour
DOI :
10.1109/TIM.2005.843566
Filename :
1408276
Link To Document :
بازگشت