• DocumentCode
    748249
  • Title

    APMP international comparison of AC-DC transfer standards at the lowest attainable level of uncertainty

  • Author

    Budovsky, Ilya ; Abidin, Abdul Rashid Bin Zainal ; Yan, Aaron Y K ; Liu, LingXiang ; Rustagi, Vijay Kumar ; Govil, Anil Kumar ; Klonz, Manfred ; Wei, Yih-cheng ; Early, Murray D. ; Sasaki, Hitoshi ; Fujiki, Hiroyuki ; Kumtawee, Chalit ; Charoensook, Ajcha

  • Author_Institution
    Nat. Meas. Inst. of Australia, Lindfield, Australia
  • Volume
    54
  • Issue
    2
  • fYear
    2005
  • fDate
    4/1/2005 12:00:00 AM
  • Firstpage
    795
  • Lastpage
    798
  • Abstract
    This paper presents preliminary results of the APMP.EM-K6a key comparison of AC-DC transfer conducted during 2000 to 2003. The AC-DC voltage transfer difference of the travelling standard was measured at 3 V and selected frequencies from 1 kHz to 1 MHz that included those of the CCEM-K6a key comparison. Also discussed are the methods used to compare thermal voltage converters with different input connectors, and to link the results to the parent Consultative Committee on Electricity and Magnetism (CCEM) comparison.
  • Keywords
    calibration; convertors; frequency measurement; transfer standards; voltage measurement; 0.001 to 1 MHz; 3 V; APMP.EM-K6; Consultative Committee on Electricity and Magnetism; ac-dc transfer standards; input connectors; thermal voltage converters; travelling standard; uncertainty level; Australia; Connectors; Energy conversion; Frequency measurement; Laboratories; Measurement standards; Metrology; Thermal resistance; Uncertainty; Voltage; AC–DC transfer; international comparison; thermal voltage converter;
  • fLanguage
    English
  • Journal_Title
    Instrumentation and Measurement, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0018-9456
  • Type

    jour

  • DOI
    10.1109/TIM.2004.843088
  • Filename
    1408291