Title :
Design and development of an MR-compatible PET scanner for imaging small animals
Author :
Mackewn, Jane E. ; Strul, D. ; Hallett, W.A. ; Halsted, P. ; Page, R.A. ; Keevil, S.F. ; Williams, S.C.R. ; Cherry, S.R. ; Marsden, P.K.
Author_Institution :
King´´s Coll. London, UK
Abstract :
A single-slice magnetic resonance (MR) compatible positron emission tomography (PET) system with a transaxial field of view ∼6 cm has been designed and is currently under construction. It will consist of four concentric rings of lutetium oxyorthosilicate (LSO) scintillation crystals, each coupled to one of eight multi-channel photomultiplier tubes (PMTs) via 3.5 m optical fibers. The annulus containing the crystals has an outside diameter of 12 cm and is placed within the MR field of view whilst the PMTs are located outside the main magnetic field. A highly reproducible method that optimizes the amount of scintillation light that reaches the PMTs has been established. Two small sections of the scanner, each containing 4 by 4 crystal arrays, demonstrated good flood position histograms with all sixteen channels clearly identifiable. The light loss through a fiber of length of 3.25 m was approximately 70%. The spatial resolution of the two arrays in coincidence was measured at 1.6 mm full-width half-maximum (FWHM), and the temporal resolution of one array in coincidence with a single LSO crystal was measured to be 10.9 ns. The design incorporates a novel technique for improving sampling at the center of the field of view within the scanner. The concentric rings are offset with respect to one another by one quarter of the crystal width between layers resulting in significantly improved sampling. The results indicate that the PET scanner will have a performance comparable with that of current small animal systems and it will be used to investigate the utility and potential applications of combining PET and MR in small animals.
Keywords :
biomedical MRI; optical fibres; photomultipliers; positron emission tomography; scintillation counters; MR-compatible PET scanner; concentric rings; crystal arrays; crystal width; flood position histograms; full-width half-maximum; lutetium oxyorthosilicate scintillation crystals; magnetic field; multichannel photomultiplier tubes; multimodality; optical fibers; scintillation light; single-slice magnetic resonance compatible positron emission tomography system; small animal systems; spatial resolution; temporal resolution; transaxial field; Animals; Crystals; Magnetic field measurement; Magnetic resonance; Magnetic resonance imaging; Optical fibers; Optical imaging; Positron emission tomography; Sampling methods; Spatial resolution; Dectecors; magnetic resonance; multimodality; positron emission tomography; sampling;
Journal_Title :
Nuclear Science, IEEE Transactions on
DOI :
10.1109/TNS.2005.858260