The author comments on the paper by R.D. Henderson and P.J. Rose (see ibid., vol.30, no.3, 1994) suggesting that four points are subject to misinterpretation. These are related to: mixed references to voltage harmonics and current harmonics; K-rated transformers; transformer derating factor; and harmonics attenuation by an isolation transformer. The authors of the original article reply to the comments.<>
Keywords :
electric drives; industrial power systems; power supply quality; power system harmonics; power transformers; K-rated transformers; SCR drives; current harmonics; harmonics attenuation; industrial power system; isolation transformer; power quality; transformer derating factor; voltage harmonics; Attenuation; Current measurement; Eddy currents; Frequency; Inductors; Power quality; Power system harmonics; Stress; Thyristors; Transformers;