    Stabilizing scintillation detector systems by exploiting the temperature dependence of the light pulse decay time

  • Author

    Pausch, Guntram ; Stein, Jurgen ; Teofilov, Nikolai

  • Author_Institution
    Target Systemelectronic Gmbh, Solingen, Germany
  • Volume
    52
  • Issue
    5
  • fYear
    2005
  • Firstpage
    1849
  • Lastpage
    1855
  • Abstract
    Scintillation detectors must tolerate a wide range of ambient temperatures and strong temperature slopes when used in outdoor applications. Such demanding conditions are typical for all homeland security applications. An effective and efficient detector stabilization compensating for temperature dependent gain shifts is essential to maintain energy calibration and resolution. Reliable, well-established solutions are based on radioactive reference sources; however, alternatives are much asked for. The gain shift correction for the temperature dependence of the scintillation light output requires elaborate hardware and software means without a reference source. Strong and rapid temperature changes further complicate the situation as there is no thermal equilibrium in the detector but rather a temperature field. This paper presents a new technique of gain stabilization which considers the effective scintillator temperature by analyzing the average pulse shape of detector signals. The pulse shape is correlated with the scintillation light decay time. This parameter can be extracted online from digitized detector signals. The decay time data are used to eliminate all the temperature determined system gain shifts without radioactive reference source. This technique has been verified in extensive climate chamber measurements. The results are discussed.
  • Keywords
    gamma-ray detection; pulse shaping; radioactive sources; solid scintillation detectors; decay time data; detector stabilization; digital signal processors; digitized detector signals; effective scintillator temperature; extensive climate chamber measurements; gamma-ray spectroscopy; homeland security applications; light pulse decay time; pulse shape; radioactive reference sources; scintillation detectors; temperature dependent gain shifts; thermal equilibrium; Calibration; Maintenance; Pulse shaping methods; Scintillation counters; Shape; Signal detection; Solid scintillation detectors; Temperature dependence; Temperature distribution; Terrorism; Detectors; digital signal processors; gamma-ray spectroscopy; pulse analysis; scintillation detectors; signal processing; stability; temperature;
  • fLanguage
    English
  • Journal_Title
    Nuclear Science, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0018-9499
  • Type

    jour

  • DOI
    10.1109/TNS.2005.856616
  • Filename
    1546514