• DocumentCode
    749711
  • Title

    3-D position sensitive CdZnTe spectrometer performance using third generation VAS/TAT readout electronics

  • Author

    Zhang, Feng ; He, Zhong ; Knoll, Glenn F. ; Wehe, David K. ; Berry, James E.

  • Author_Institution
    Dept. of Nucl. Eng. & Radiol. Sci., Univ. of Michigan, Ann Arbor, MI, USA
  • Volume
    52
  • Issue
    5
  • fYear
    2005
  • Firstpage
    2009
  • Lastpage
    2016
  • Abstract
    Three-dimensional (3-D) position-sensitive CdZnTe (CZT) gamma-ray spectrometers employing new VAS3.1/TAT3 ASIC readouts were developed and tested. Each spectrometer is a 1.5 × 1.5 × 1 cm3 CdZnTe crystal with 11 × 11 pixellated anodes wire-bonded to the readout electronics using an intermediate ceramic substrate with plated-through-via. The signals from the anode pixels and the cathode were all read out using these ASICs. The pixel position provides the lateral coordinates of interactions, while the cathode to anode signal ratio and electron drift times are used to obtain interaction depths. Using the 3-D position information, the variation in weighting potential, electron trapping and material nonuniformity can be accounted for to the scale of the position resolution, ∼1.27 × 1.27 × 0.2 mm. The new VAS3.1/TAT3 ASIC has less gain and baseline drift, lower cross-talk noise, more uniform thresholds, better linearity and better timing resolution than our previous VAS2/TAT2 system. For example, the 32 keV K X-ray from a 137Cs source was observed for the first time. Two 3-D position sensitive CZT spectrometers were tested and both achieved better than 1% FWHM energy resolution (at 662 keV, room temperature operation, with an uncollimated source) for single-pixel events. The experimental results for these two 3-D position sensitive CZT spectrometer systems are presented and discussed.
  • Keywords
    application specific integrated circuits; gamma-ray detection; gamma-ray spectroscopy; high energy physics instrumentation computing; nuclear electronics; position sensitive particle detectors; readout electronics; semiconductor counters; 3-D position information; 3-D position sensitive CdZnTe gamma-ray spectrometer performance; 137Cs source; FWHM energy resolution; X-ray; baseline drift; electron drift times; electron trapping; intermediate ceramic substrate; lateral coordinates; lower cross-talk noise; material nonuniformity; pixel position; pixellated anodes; room temperature operation; single-pixel events; third generation VAS3.1/TAT3 ASIC readout electronics; timing resolution; uncollimated source; weighting potential; Anodes; Application specific integrated circuits; Cathodes; Ceramics; Electron traps; Energy resolution; Readout electronics; Signal resolution; Spectroscopy; Testing; CZT; CdZnTe; gamma-ray spectroscopy; position sensitive; spectrometer; three-dimensional (3-D);
  • fLanguage
    English
  • Journal_Title
    Nuclear Science, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0018-9499
  • Type

    jour

  • DOI
    10.1109/TNS.2005.856821
  • Filename
    1546545