DocumentCode :
750187
Title :
Development and characterisation of tissue equivalent materials for frequency range 30-300MHz
Author :
Peyman, A. ; Gabriel, C.
Volume :
43
Issue :
5
fYear :
2007
Firstpage :
19
Lastpage :
20
Abstract :
Two formulations for tissue equivalent liquids are presented and characterised in terms of dielectric properties in the frequency range 30-300 MHz. The purpose is to provide viable options for consideration by the standardisation bodies dealing with the assessment of exposure to electromagnetic sources in that frequency range
Keywords :
biological effects of fields; dielectric liquids; electrical conductivity; permittivity; 20 C; 30 to 300 MHz; VHF; diacetin based solutions; dielectric properties; electromagnetic sources; sucrose based solutions; tissue equivalent materials;
fLanguage :
English
Journal_Title :
Electronics Letters
Publisher :
iet
ISSN :
0013-5194
Type :
jour
DOI :
10.1049/el:20073455
Filename :
4137465
Link To Document :
بازگشت