Measurement of partial discharges at rapidly changing voltages
Author
Lindell, Elisabeth ; Bengtsson, Tord ; Blennow, Jörgen ; Gubanski, Stanislaw M.
Author_Institution
Dept. of Mater. & Manuf. Technol., Chalmers Univ. of Technol., Goteborg
Volume
15
Issue
3
fYear
2008
fDate
6/1/2008 12:00:00 AM
Firstpage
823
Lastpage
831
Abstract
This work presents a measuring system for PDs at repetitive voltages with short rise times, based on a coupling device adapted for this kind of voltages and a method for removing contributions from the applied voltage. The potential of the system has been demonstrated through measurements of PDs around a needle in air at voltages of 5.5 kV - 9.5 kV with rise times down to 10 mus. The observations obtained with this PD source prove that the measuring technique described enables detailed studies of PD properties under repetitive rapidly changing voltage waveforms in the investigated range of voltages and rise times.
Keywords
partial discharge measurement; PD source; coupling device; partial discharge measurement; voltage 5.5 kV to 9.5 kV; voltage waveforms; Circuits; Filters; Frequency measurement; IEC standards; Insulation; Partial discharges; Pulse measurements; Pulse width modulation; Time measurement; Voltage;