• DocumentCode
    752606
  • Title

    Profiling a reactor component using ultrasonics

  • Author

    Pathak, L.

  • Author_Institution
    Indira Gandhi Centre for Atomic Res., Kalpakkam
  • Volume
    42
  • Issue
    2
  • fYear
    1995
  • fDate
    4/1/1995 12:00:00 AM
  • Firstpage
    110
  • Lastpage
    114
  • Abstract
    Nuclear reactors have many components within the reactor vessel. During the life of a reactor it is possible for these components to be displaced or deformed because of the thermal cycles to which they are subject. Also, these components are handled during refuellings and reconfigurations of the core. During these operations, damage is possible. Inspection of these components in situ therefore becomes important for the upkeep of the reactor. However, high radiation levels make it difficult to monitor using optical methods. This paper describes an ultrasonic method which was successfully employed in profiling a deformed guide tube of a reactor. The method uses the well-known ultrasonic ranging technique. However, the speciality of the method is the use of air transducers at 40 kHz to overcome the inherent divergence problems and the difficulties associated with high temperatures inherent in a sodium cooled reactor
  • Keywords
    fission reactor materials; fission reactor safety; inspection; ultrasonic materials testing; Na cooled reactor; air transducers; deformed guide tube; divergence problems; high radiation levels; high temperatures; inspection; nuclear reactor vessel component profiling; reconfigurations; refuellings; thermal cycles; ultrasonic ranging; ultrasonics; Biomedical optical imaging; Fission reactors; Fuels; Holographic optical components; Holography; Inductors; Inspection; Radiation monitoring; Ultrasonic imaging; Vibration measurement;
  • fLanguage
    English
  • Journal_Title
    Nuclear Science, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0018-9499
  • Type

    jour

  • DOI
    10.1109/23.372139
  • Filename
    372139