Combined MR data acquisition of multicontrast images using variable acquisition parameters and K-space data sharing
Author :
Mekle, Ralf ; Laine, Andrew F. ; Wu, Ed X.
Author_Institution :
Dept. of Biomed. Eng., Columbia Univ., New York, NY, USA
fDate :
7/1/2003 12:00:00 AM
Abstract :
A new technique to reduce clinical magnetic resonance imaging (MRI) scan time by varying acquisition parameters and sharing k-space data between images, is proposed. To improve data utilization, acquisition of multiple images of different contrast is combined into a single scan, with variable acquisition parameters including repetition time (TR), echo time (TE), and echo train length (ETL). This approach is thus referred to as a "combo acquisition." As a proof of concept, simulations of MRI experiments using spin echo (SE) and fast SE (FSE) sequences were performed based on Bloch equations. Predicted scan time reductions of 25%-50% were achieved for 2-contrast and 3-contrast combo acquisitions. Artifacts caused by nonuniform k-space data weighting were suppressed through semi-empirical optimization of parameter variation schemes and the phase encoding order. Optimization was assessed by minimizing three quantitative criteria: energy of the "residue point spread function (PSF)," energy of "residue profiles" across sharp tissue boundaries, and energy of "residue images." In addition, results were further evaluated by quantitatively analyzing the preservation of contrast, the PSF, and the signal-to-noise ratio. Finally, conspicuity of lesions was investigated for combo acquisitions in comparison with standard scans. Implications and challenges for the practical use of combo acquisitions are discussed.
Keywords :
biomedical MRI; brain; data acquisition; image sequences; medical image processing; optimisation; Bloch equations; combined MR data acquisition; k-space data sharing; lesions conspicuity; magnetic resonance imaging; medical diagnostic imaging; multicontrast images; parameter variation schemes; phase encoding order; quantitative criteria minimization; residue point spread function; residue profiles energy; semiempirical optimization; sharp tissue boundaries; signal-to-noise ratio; spin echo sequence; variable acquisition parameters; Biomedical engineering; Data acquisition; Encoding; Equations; Image analysis; Magnetic resonance imaging; Radiology; Signal analysis; Signal to noise ratio; Tellurium; Algorithms; Brain; Humans; Image Enhancement; Imaging, Three-Dimensional; Magnetic Resonance Imaging; Phantoms, Imaging; Quality Control; Signal Processing, Computer-Assisted; Subtraction Technique;
Journal_Title :
Medical Imaging, IEEE Transactions on
DOI :
10.1109/TMI.2003.815054