• DocumentCode
    756247
  • Title

    Comparison of electrical aging tests on EPR-insulated minicables and ribbons from full-sized EPR cable

  • Author

    Mazzanti, G. ; Montanari, Gian ; Motori, A. ; Anelli, P.

  • Author_Institution
    Dipartimento di Ingegneria Elettrica, Bologna Univ.
  • Volume
    2
  • Issue
    6
  • fYear
    1995
  • fDate
    12/1/1995 12:00:00 AM
  • Firstpage
    1095
  • Lastpage
    1099
  • Abstract
    The results of electrical endurance tests performed on ribbons cut from full-sized EPR cables are compared with those obtained by tests performed on cable models, having the same insulation as the full-sized cable. It is shown that the voltage endurance coefficient estimated on the basis of the short-term life test data has approximately the same value for cable models and ribbons, according to both inverse-power and exponential models. However, the surface roughness resulting from cutting the specimens can affect the result at high stresses
  • Keywords
    ageing; cutting; ethylene-propylene rubber; insulation testing; life testing; power cable insulation; power cable testing; surface topography; EPR-insulated minicables; cable models; cutting; electrical aging tests; electrical endurance tests; exponential models; inverse-power models; ribbons; short-term life test data; surface roughness; voltage endurance coefficient; Aging; Cable insulation; Dielectrics and electrical insulation; Insulation testing; Life estimation; Life testing; Paramagnetic resonance; Performance evaluation; Rough surfaces; Voltage;
  • fLanguage
    English
  • Journal_Title
    Dielectrics and Electrical Insulation, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    1070-9878
  • Type

    jour

  • DOI
    10.1109/94.484311
  • Filename
    484311