Title :
Comparison of electrical aging tests on EPR-insulated minicables and ribbons from full-sized EPR cable
Author :
Mazzanti, G. ; Montanari, Gian ; Motori, A. ; Anelli, P.
Author_Institution :
Dipartimento di Ingegneria Elettrica, Bologna Univ.
fDate :
12/1/1995 12:00:00 AM
Abstract :
The results of electrical endurance tests performed on ribbons cut from full-sized EPR cables are compared with those obtained by tests performed on cable models, having the same insulation as the full-sized cable. It is shown that the voltage endurance coefficient estimated on the basis of the short-term life test data has approximately the same value for cable models and ribbons, according to both inverse-power and exponential models. However, the surface roughness resulting from cutting the specimens can affect the result at high stresses
Keywords :
ageing; cutting; ethylene-propylene rubber; insulation testing; life testing; power cable insulation; power cable testing; surface topography; EPR-insulated minicables; cable models; cutting; electrical aging tests; electrical endurance tests; exponential models; inverse-power models; ribbons; short-term life test data; surface roughness; voltage endurance coefficient; Aging; Cable insulation; Dielectrics and electrical insulation; Insulation testing; Life estimation; Life testing; Paramagnetic resonance; Performance evaluation; Rough surfaces; Voltage;
Journal_Title :
Dielectrics and Electrical Insulation, IEEE Transactions on