• DocumentCode
    756358
  • Title

    Design and implementation of a fault-tolerant magnetic bearing system for turbo-molecular vacuum pump

  • Author

    Noh, Myounggyu D. ; Cho, Seong-Park ; Kyung, Jin-Ho ; Ro, Seung-Kook ; Park, Jong-Kweon

  • Author_Institution
    Dept. of Mechatronics Eng., Chungnam Nat. Univ., Daejeon, South Korea
  • Volume
    10
  • Issue
    6
  • fYear
    2005
  • Firstpage
    626
  • Lastpage
    631
  • Abstract
    One of the obstacles for a magnetic bearing for use in a wide range of industrial applications is the failure modes associated with magnetic bearings, which are not expected for conventional passive bearings. These failure modes include electric power outage, power amplifier faults, position sensor faults, and the malfunction of controllers. Fault tolerant magnetic bearing systems have been proposed so that the system can operate in spite of some faults in the system. In this paper, we describe the design and implementation of a fault tolerant magnetic bearing system for a turbo-molecular vacuum pump. The system can cope with actuator/amplifier faults, as well as faults in position sensors, which are the two major fault modes in a magnetic bearing system.
  • Keywords
    failure analysis; fault tolerance; magnetic bearings; magnetic levitation; turbomachinery; vacuum pumps; conventional passive bearings; electric power outage; fault tolerance; magnetic bearing system; magnetic levitation; position sensor faults; power amplifier faults; turbo-molecular vacuum pump; Actuators; Control systems; Fault tolerance; Fault tolerant systems; Magnetic levitation; Magnetic sensors; Power amplifiers; Redundancy; Sensor systems; Vacuum systems; Actuators; fault tolerance; magnetic levitation; sensors;
  • fLanguage
    English
  • Journal_Title
    Mechatronics, IEEE/ASME Transactions on
  • Publisher
    ieee
  • ISSN
    1083-4435
  • Type

    jour

  • DOI
    10.1109/TMECH.2005.859830
  • Filename
    1556565