• DocumentCode
    757496
  • Title

    New ZVS-PWM inverter switching limits and operating area

  • Author

    Metz, M. ; Roux, J. ; Doua, S. Ben ; Arches, J.P. ; Foch, H.

  • Author_Institution
    Inst. Nat. Polytech. de Toulouse, France
  • Volume
    139
  • Issue
    2
  • fYear
    1992
  • fDate
    3/1/1992 12:00:00 AM
  • Firstpage
    86
  • Lastpage
    95
  • Abstract
    Soft commutation (zero voltage switching or zero current switching (ZVS or ZCS)) allows high frequency operation of power static convertors, reduction of losses and parasitic interferences. The popular PWM inverter cannot naturally benefit from the soft commutation, but only slight changes are to be made to perform ZVS with a PWM inverter (equipped with its filter). A theoretical approach deals with power convertors using soft commutation and the resulting switching limits; it shows that only little restriction in the operating area is induced by these switching conditions. Experimental results on a MOS inverter and a GTO validate this analysis
  • Keywords
    invertors; pulse width modulation; switching; GTO thyristor; MOS inverter; ZVS-PWM inverter; operating area; soft commutation; switching limits; zero voltage switching;
  • fLanguage
    English
  • Journal_Title
    Electric Power Applications, IEE Proceedings B
  • Publisher
    iet
  • ISSN
    0143-7038
  • Type

    jour

  • Filename
    121770