• DocumentCode
    760701
  • Title

    The influence of the test fixture on shielding effectiveness measurements

  • Author

    Catrysse, J. ; Delesie, M. ; Steenbakkers, W.

  • Author_Institution
    Katholieke Ind. Hogeschool, Oostende, Belgium
  • Volume
    34
  • Issue
    3
  • fYear
    1992
  • fDate
    8/1/1992 12:00:00 AM
  • Firstpage
    348
  • Lastpage
    351
  • Abstract
    In the past, different test cells were used to measure the shielding effectiveness (SE) of materials against electromagnetic radiation, for far-field (or plane wave) conditions. Recently, a new standard was approved. However, some errors may occur, especially in the case of filled conductive plastics, where the conductive layer is not directly accessible from the surface of the material. As well as reporting on some of the difficulties and problems encountered when measuring the SE of this family of materials, the authors propose a different technique for measuring far-field conditions
  • Keywords
    electric variables measurement; measurement errors; measurement standards; shielding; test equipment; ASTM-D4935/89 cell; ASTM-ES7 cell; TEM-t cell; electromagnetic radiation; far-field conditions; filled conductive plastics; measurement errors; shielding effectiveness measurements; standard test cells; test fixture influence; Cable shielding; Conducting materials; Connectors; Electromagnetic measurements; Electromagnetic radiation; Fixtures; Materials testing; Plastics; Seals; Sheet materials;
  • fLanguage
    English
  • Journal_Title
    Electromagnetic Compatibility, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0018-9375
  • Type

    jour

  • DOI
    10.1109/15.155853
  • Filename
    155853