Abstract
Measurements that show significant differences between currents measured in individual wires of a bundle due to equal current excitations by external radiated fields or by bulk injection are reported. This raises concern whether bulk current injection is a reliable technique for EMC work
Keywords
electric current measurement; electromagnetic compatibility; EMC; aircraft wiring; bulk injection; current excitations; current measurement; external radiated fields; individual wires; military aircraft; Aerospace electronics; Aircraft; Antenna measurements; Clamps; Current measurement; Electromagnetic compatibility; Radio frequency; Testing; Wires; Wiring;