Title :
On the use of an ionic pump in a convector heater
Author_Institution :
Lab. d´´Electrostat. et de Mater. Dielectr., CNRS, Grenoble, France
Abstract :
The possible use of an ionic pump in order to increase the air flux in a convector heater is examined. The functioning of such an electro-aerodynamic heater is modeled. The distribution of space charge injected by a set of point electrodes and the influence of the temperature of the heating resistor on back emission and breakdown voltage are more particularly studied. The results on a test cell and on a prototype agree with the prediction of a mean flow velocity varying as the square root of the product Id of the current I and the gap d of the pumping device. The problems met in practical application are briefly discussed
Keywords :
convection; corona; electrodes; ion pumps; resistance heating; space charge; air flux increase; back emission; breakdown voltage; convector heater; corona; electro-aerodynamic heater; heating resistor temperature; ionic pump; mean flow velocity; point electrodes; space charge distribution; space charge injection; Corona; Ducts; Electrodes; Heat pumps; Heating; Permittivity; Resistors; Space charge; Temperature; Voltage;
Journal_Title :
Industry Applications, IEEE Transactions on