DocumentCode
764716
Title
Variable-voltage diode convertor rolling-stock transformers to control DC traction motors
Author
Marsden, D.J.
Author_Institution
GEC Alsthom Transformers Ltd., Stafford, UK
Volume
139
Issue
3
fYear
1992
fDate
5/1/1992 12:00:00 AM
Firstpage
197
Lastpage
208
Abstract
The first generation of traction transformers used on railway vehicles in the UK, which went into service in the early 1960s, transformed the 50 Hz overhead supply voltage of 25 kV or 6.25 kV down to an acceptable voltage for diode convertors supplying DC traction motors. They also had to vary the output voltage by providing voltage tappings on the transformer windings, selected by on-load tapchangers. They were originally required to supply mercury arc rectifiers but these were replaced by silicon rectifiers, which made transformer operating conditions less arduous. After more than 25 years service they still perform reliably, provided that their on-load tapchangers are maintained regularly and simple routine maintenance checks are carried out
Keywords
DC motors; electric locomotives; machine control; power convertors; traction; transformers; 25 kV; 50 Hz; 6.25 kV; DC traction motors; electric locomotives; on-load tapchangers; railway vehicles; rolling-stock transformers; routine maintenance checks; transformer windings; variable-voltage diode convertors;
fLanguage
English
Journal_Title
Electric Power Applications, IEE Proceedings B
Publisher
iet
ISSN
0143-7038
Type
jour
Filename
141480
Link To Document