DocumentCode :
765824
Title :
Evaluation of statistical methods of image reconstruction through ROC analysis [emission tomography]
Author :
Gooley, T.A. ; Barrett, H.H.
Author_Institution :
Dept. of Radiol., Arizona Univ., Tucson, AZ, USA
Volume :
11
Issue :
2
fYear :
1992
fDate :
6/1/1992 12:00:00 AM
Firstpage :
276
Lastpage :
283
Abstract :
Several statistical methods of image reconstruction are described and objectively compared through the use of receiver-operating-characteristic (ROC) analysis based on a specified detection task performed by a human observer. The simulated imaging system is a multiple-pinhole coded-aperture system for dynamic cardiac imaging, and the objects represent cross sections of the left ventricle at end systole. The task is detection of a profusion representing an akinetic wall segment. Thirteen different reconstruction algorithms are considered. Human observers perform the specified task on this set of reconstructions, and the results are analyzed through the use of ROC analysis. The results show that the methods that utilize the largest amount of (accurate) prior information tend to perform the best
Keywords :
cardiology; computerised tomography; radioisotope scanning and imaging; akinetic wall segment; detection task; dynamic cardiac imaging; emission tomography; end systole; image reconstruction; left ventricle cross sections; multiple-pinhole coded-aperture system; receiver-operating-characteristic analysis; reconstruction algorithms; statistical methods; Humans; Image analysis; Image reconstruction; Maximum likelihood detection; Maximum likelihood estimation; Performance analysis; Radiology; Reconstruction algorithms; Statistical analysis; Tomography;
fLanguage :
English
Journal_Title :
Medical Imaging, IEEE Transactions on
Publisher :
ieee
ISSN :
0278-0062
Type :
jour
DOI :
10.1109/42.141652
Filename :
141652
Link To Document :
بازگشت