• DocumentCode
    766994
  • Title

    Ground-based sensing of water vapor in the stratosphere and mesosphere

  • Author

    Thacker, Dorsey L. ; Bevilacqua, R.M. ; Waltman, W.B. ; Pauls, T.A. ; Gomez, R.M. ; Nedoluha, G.E. ; Schwartz, P.R.

  • Author_Institution
    Interferometrics Inc., Vienna, VA, USA
  • Volume
    44
  • Issue
    2
  • fYear
    1995
  • fDate
    4/1/1995 12:00:00 AM
  • Firstpage
    355
  • Lastpage
    359
  • Abstract
    We report on new developments of the WVMS instrument that provide extended altitude coverage (25-75 km) and precision that have not been achieved before with ground based microwave remote sensing of water vapor. This paper emphasizes the technical details of the instrument, experimental techniques, and especially accuracy and calibration issues
  • Keywords
    atmospheric techniques; calibration; humidity measurement; microwave measurement; monitoring; radiometry; remote sensing; stratosphere; 25 to 75 km; H2O; WVMS instrument; accuracy; calibration; ground-based sensing; linearity; mesosphere; microwave remote sensing; stratosphere; water vapor; Atmospheric measurements; Bandwidth; Calibration; Instruments; Pressure measurement; Remote sensing; Shape measurement; Spectroscopy; Temperature; Terrestrial atmosphere;
  • fLanguage
    English
  • Journal_Title
    Instrumentation and Measurement, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0018-9456
  • Type

    jour

  • DOI
    10.1109/19.377851
  • Filename
    377851