DocumentCode
767026
Title
Very low frequency ac-dc transfer standard
Author
Budovsky, Ilya
Author_Institution
Div. of Appl. Phys., CSIRO, Lindfield, NSW, Australia
Volume
44
Issue
2
fYear
1995
fDate
4/1/1995 12:00:00 AM
Firstpage
367
Lastpage
369
Abstract
A low frequency ac-dc transfer standard has been developed to satisfy the NML demand for very low frequency ac-dc transfer calibrations. Tests performed using digitally synthesized signals and synchronised dc measurements showed less than 13 parts per million variation in the ac-dc difference of the standard within the frequency range 0.01 to 100 Hz
Keywords
calibration; electric current measurement; measurement standards; voltage measurement; 0.01 to 100 Hz; NML; ac-dc difference; calibration; digitally synthesized signals; low frequency ac-dc transfer standard; synchronised dc measurements; Analog-digital conversion; Calibration; Frequency conversion; Frequency synchronization; Measurement standards; Performance evaluation; Standards development; Temperature; Testing; Voltage;