DocumentCode :
767070
Title :
AC-DC difference characteristics of high-voltage thermal converters
Author :
Huang, D.X. ; Lipe, Thomas E. ; Kinard, Joseph R. ; Childers, Clifton B.
Author_Institution :
Div. of Electr., Nat. Inst. of Stand. & Technol., Gaithersburg, MD, USA
Volume :
44
Issue :
2
fYear :
1995
fDate :
4/1/1995 12:00:00 AM
Firstpage :
387
Lastpage :
390
Abstract :
This paper describes a study of high-voltage thermal converters (HVTC´s) at voltages above 100 V at frequencies up to 100 kHz. Techniques for the construction of HVTC´s are described, and the effects of aging and dielectric loss on the resistor, changes in the timing sequence of ac-dc difference tests, relay dead-times, warmup times, and voltage level dependence are given
Keywords :
ageing; dielectric losses; high-voltage techniques; measurement standards; thermoelectric devices; voltage measurement; 100 V; 100 kHz; AC-DC difference characteristics; high-voltage thermal converters; Analog-digital conversion; Capacitance; Dielectric losses; Dielectric substrates; Engine cylinders; Frequency; Laboratories; Resistors; Tellurium; Voltage;
fLanguage :
English
Journal_Title :
Instrumentation and Measurement, IEEE Transactions on
Publisher :
ieee
ISSN :
0018-9456
Type :
jour
DOI :
10.1109/19.377860
Filename :
377860
Link To Document :
بازگشت