Title :
Dual heater isothermal AC/DC converter
Author_Institution :
740 Park Avenue, Hoboken, NJ, USA
fDate :
4/1/1995 12:00:00 AM
Abstract :
A dual heater isothermal AC/DC converter has been developed and tested experimentally. The device used in a negative feedback loop, driven by a sinusoidal voltage yields the rms value. At low frequencies the major source of error is the ripple in the feedback path. A minor systematic error, at a all frequencies, is an inverse function of the loop gain
Keywords :
convertors; electric current measurement; electric heating; electrical engineering computing; feedback; measurement errors; measurement standards; thermocouples; voltage measurement; dual heater isothermal ac/dc converter; Circuits; DC-DC power converters; Electric resistance; Feedback loop; Frequency; Isothermal processes; Output feedback; Temperature; Thermal resistance; Voltage;
Journal_Title :
Instrumentation and Measurement, IEEE Transactions on