• DocumentCode
    768412
  • Title

    Drain AM frequency response of the high-Q Class E power amplifier

  • Author

    Kimber, D.P. ; Gardner, P.

  • Author_Institution
    Electron., Univ. of Birmingham, UK
  • Volume
    152
  • Issue
    6
  • fYear
    2005
  • Firstpage
    752
  • Lastpage
    756
  • Abstract
    The Class E power amplifier has very high drain efficiency under quasi-static conditions, and is a good candidate for EER or polar techniques. The load presented by the PA to the high level amplitude modulator can be modelled by an equivalent circuit. This allows the modulation frequency response and excess switch dissipation to be calculated. It is found that the feed choke and the finite Q of the output circuit interact to form a second order low pass filter. Reasonable agreement with measured data is seen.
  • Keywords
    amplitude modulation; equivalent circuits; frequency response; low-pass filters; power amplifiers; AM frequency response; EER; drain efficiency; equivalent circuit; excess switch dissipation; feed choke; high level amplitude modulator; high-Q class E power amplifier; modulation frequency response; polar techniques; quasi-static conditions; second order low pass filter;
  • fLanguage
    English
  • Journal_Title
    Circuits, Devices and Systems, IEE Proceedings
  • Publisher
    iet
  • ISSN
    1350-2409
  • Type

    jour

  • DOI
    10.1049/ip-cds:20045219
  • Filename
    1561714