DocumentCode
768471
Title
Corona deterioration reduction in large electrical machine insulation
Author
Rehder, R.H. ; Stutt, M.E.
Author_Institution
Gen. Electr. Canada, Peterborough, Ont., Canada
Volume
1
Issue
1
fYear
1995
Firstpage
12
Lastpage
15
Abstract
Partial discharge or corona activity in the insulation system of large electric machine stators has caused deterioration of these machines, and in some cases resulted in premature failures. Development work is being done to better understand the cause and effects of this corona activity. Efforts are centering around the increased use of corona-resistant material, and the reduced use of corona-sensitive materials. Some of the developments are described in this paper
Keywords
corona; electric breakdown; insulation testing; machine insulation; machine testing; partial discharges; stators; corona activity; corona-resistant material; corona-sensitive materials; developments; electrical machine insulation; partial discharge; stators; Chemical industry; Coils; Conducting materials; Corona; Dielectric materials; Dielectrics and electrical insulation; Partial discharges; Production; Stress; Voltage;