DocumentCode :
771944
Title :
Magnetic Field Analysis in Buried Pipe Detection
Author :
Wasa, Y. ; Kondo, Y. ; Yamauchi, F. ; Miyamoto, Y.
Author_Institution :
NEC Corp.
Volume :
2
Issue :
12
fYear :
1987
Firstpage :
1120
Lastpage :
1121
Abstract :
Mangetic detection is known as a useful method to detect the position of a buried pipe. The detection, however, becomes erroneous except in the case of a single pipe-line. We have considered a case of two pipe-lines running parallel each other to gain a theoretical understanding of the error cause, and compared the results analyzed to those experimentally measured. Both results are in good agreement. The error is due to an earth current leaking from a considered line toward another line nearby.
Keywords :
Current density; Current measurement; Earth; Gain measurement; Leak detection; Leakage current; Magnetic analysis; Magnetic field measurement; Magnetic fields; Voltage;
fLanguage :
English
Journal_Title :
Magnetics in Japan, IEEE Translation Journal on
Publisher :
ieee
ISSN :
0882-4959
Type :
jour
DOI :
10.1109/TJMJ.1987.4549710
Filename :
4549710
Link To Document :
بازگشت