Title :
Coaxial shunt intended for transient current measurement in a pseudospark switch
Author :
Moran, P. ; Gibert, A. ; Francois, G. Jean ; Pignolet, P.
Author_Institution :
Pau Univ., France
fDate :
3/1/1996 12:00:00 AM
Abstract :
In a pseudospark discharge, a fast breakdown phase appears, during which a high density charge particle beam is extracted from electrodes, corresponding to a fast rise of about 1011 A/s. To achieve this, a mainly ohmic coaxial shunt for transient current measurement was realised (200 MHz bandwidth and 1 kA upper limit for measurable current), to avoid the earthed inductance influence. Measurement accuracy allowed an energetic balance of the switching to be drawn up with the appropriate time resolution
Keywords :
electric breakdown; electric current measurement; plasma probes; pulsed power switches; spark gaps; sparks; 1 kA; 200 MHz; Faraday cage; current probe; fast breakdown phase; fast rise; high density charge particle beam; measurement accuracy; ohmic coaxial shunt; pseudospark discharge; pseudospark switch; ring shaped resistor; transient current measurement;
Journal_Title :
Science, Measurement and Technology, IEE Proceedings -
DOI :
10.1049/ip-smt:19960025