Title
Coaxial shunt intended for transient current measurement in a pseudospark switch
Author
Moran, P. ; Gibert, A. ; Francois, G. Jean ; Pignolet, P.
Author_Institution
Pau Univ., France
Volume
143
Issue
2
fYear
1996
fDate
3/1/1996 12:00:00 AM
Firstpage
119
Lastpage
124
Abstract
In a pseudospark discharge, a fast breakdown phase appears, during which a high density charge particle beam is extracted from electrodes, corresponding to a fast rise of about 1011 A/s. To achieve this, a mainly ohmic coaxial shunt for transient current measurement was realised (200 MHz bandwidth and 1 kA upper limit for measurable current), to avoid the earthed inductance influence. Measurement accuracy allowed an energetic balance of the switching to be drawn up with the appropriate time resolution
Keywords
electric breakdown; electric current measurement; plasma probes; pulsed power switches; spark gaps; sparks; 1 kA; 200 MHz; Faraday cage; current probe; fast breakdown phase; fast rise; high density charge particle beam; measurement accuracy; ohmic coaxial shunt; pseudospark discharge; pseudospark switch; ring shaped resistor; transient current measurement;
fLanguage
English