DocumentCode :
774325
Title :
Linac Alignnent Techniques
Author :
Herrmannsfeldt, W.B.
Author_Institution :
Stanford Linear Accelerator Center Stanford University, Stanford, California
Volume :
12
Issue :
3
fYear :
1965
fDate :
6/1/1965 12:00:00 AM
Firstpage :
9
Lastpage :
18
Abstract :
Techniques of aligning linear accelerators are discussed with specific reference to the alignment system of the two-mile accelerator. This system uses a "three-point" method by which a point which is to be aligned is brought into coincidence with the line as defined by its end points. The end points are a laser and a photo-electric detector. A rectangular Fresnel lens is located at each point to be aligned to define the "third point."
Keywords :
Apertures; Detectors; Fasteners; Lenses; Lifting equipment; Light sources; Linear accelerators; Linear particle accelerator; Structural beams; Telescopes;
fLanguage :
English
Journal_Title :
Nuclear Science, IEEE Transactions on
Publisher :
ieee
ISSN :
0018-9499
Type :
jour
DOI :
10.1109/TNS.1965.4323586
Filename :
4323586
Link To Document :
بازگشت