Title :
Linac Alignnent Techniques
Author :
Herrmannsfeldt, W.B.
Author_Institution :
Stanford Linear Accelerator Center Stanford University, Stanford, California
fDate :
6/1/1965 12:00:00 AM
Abstract :
Techniques of aligning linear accelerators are discussed with specific reference to the alignment system of the two-mile accelerator. This system uses a "three-point" method by which a point which is to be aligned is brought into coincidence with the line as defined by its end points. The end points are a laser and a photo-electric detector. A rectangular Fresnel lens is located at each point to be aligned to define the "third point."
Keywords :
Apertures; Detectors; Fasteners; Lenses; Lifting equipment; Light sources; Linear accelerators; Linear particle accelerator; Structural beams; Telescopes;
Journal_Title :
Nuclear Science, IEEE Transactions on
DOI :
10.1109/TNS.1965.4323586