• DocumentCode
    776931
  • Title

    Studies on Loss Aging in Submarine Coaxial Cable During Storage

  • Author

    Ashiya, Fumihiro ; Furukawa, Shin-Ichi ; Negishi, Yukiyasu ; Kojima, Nobuya

  • Author_Institution
    Nippon Telegraph and Telephone Public Corp., Ibaraki-ken, Japan
  • Volume
    33
  • Issue
    9
  • fYear
    1985
  • fDate
    9/1/1985 12:00:00 AM
  • Firstpage
    945
  • Lastpage
    954
  • Abstract
    Attenuation loss change in submarine coaxial cables during 4 years of storage has been measured. Attenuation loss is shown to increase for one year after manufacturing. Then, loss is also shown to increase during summer (May to October) and to stay constant or to decrease during winter (November to April of the next year). This work concentrates on the causes and an estimation method of loss aging. The first part of the paper covers experimental results on the cable aging phenomenon. The second part discusses various factors affecting loss aging, and shows that fretting corrosion on the outer conductor tape will be a main factor. The third part describes an estimation method for and countermeasures to avoid loss aging during cable storage.
  • Keywords
    Communication system maintenance; Corrosion; Underwater communication cables; Aging; Attenuation; Coaxial cables; Corrosion; Dielectric losses; Manufacturing; Material storage; Ocean temperature; Underwater vehicles; Water storage;
  • fLanguage
    English
  • Journal_Title
    Communications, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0090-6778
  • Type

    jour

  • DOI
    10.1109/TCOM.1985.1096404
  • Filename
    1096404