DocumentCode :
778360
Title :
Rejection of Nal Pulse Pile-Up in Linac Bremsstrahlung Measurements
Author :
McGuire, R.L. ; Sandifer, C.W.
Author_Institution :
Edgerton, Germeshausen & Grier, Inc. Santa Barbara, California
Volume :
13
Issue :
1
fYear :
1966
Firstpage :
315
Lastpage :
320
Abstract :
A pulse pile-up rejection system was developed and used successfully with a NaI gamma spectrometer to measure the bremsstrahlung spectral distribution from a 0.2-radiation-length gold-tungsten target bombarded by high energy electrons from a pulsed electron linear accelerator. The system utilizes a double differentiation technique to reject those scintillation events where more than one gamma ray is detected during a single linac pulse. The pulse pile-up rejection circuit was used effectively over a gamma energy range of 0.25 Mev to 21 Mev and increased data collection speed by about a factor of 20. The performance of the system agrees with theoretical predictions calculated on the basis of Poission statistics. Gamma spectral distributions measured with the system at the EG&G linac are presented to demonstrate utilization of the system.
Keywords :
Electrons; Energy measurement; Event detection; Gamma ray detection; Gamma ray detectors; Linear accelerators; Linear particle accelerator; Pulse measurements; Solid scintillation detectors; Spectroscopy;
fLanguage :
English
Journal_Title :
Nuclear Science, IEEE Transactions on
Publisher :
ieee
ISSN :
0018-9499
Type :
jour
DOI :
10.1109/TNS.1966.4323982
Filename :
4323982
Link To Document :
بازگشت