A Real-Time 2-D Vector Doppler System for Clinical Experimentation
Author :
Pastorelli, A. ; Torricelli, G. ; Scabia, M. ; Biagi, E. ; Masotti, L.
Author_Institution :
Electron. & Telecommun. Dept., Univ. of Florence, Florence
Volume :
27
Issue :
10
fYear :
2008
Firstpage :
1515
Lastpage :
1524
Abstract :
A real-time hardware software 2-D vector Doppler system has been realized by means of the FEMMINA platform. The system operates by performing two independent 1-D Doppler estimations on the scan plane of a linear array probe along different directions; the probe is connected to a commercial scanner. The reconstructed velocity is presented in real-time as superposition on the conventional B-mode images. Two different scanning techniques have been implemented, in order to carry out the 2-D Doppler investigation in the area of interest. These techniques allow to use the system both in vivo and in vivo. An extensive set of simulations has been performed in order to establish a gold standard regarding vector Doppler 2-D techniques, and to be able to assess the performance of the 2-D Doppler system by comparing simulated and experimental results. The whole real-time 2-D vector Doppler system is fully certified as hospital equipment, and thus it can be employed to carry out an experimental characterization of the 2-D Doppler technique in the clinical environment.
Keywords :
Doppler measurement; biomedical ultrasonics; blood flow measurement; cardiovascular system; diseases; image scanners; medical computing; real-time systems; vectors; FEMMINA platform; clinical experimentation; commercial scanner; conventional B-mode images; gold standard; haemodynamics; hospital equipment; independent 1-D Doppler estimations; linear array probe; real-time hardware software 2-D vector Doppler system; reconstructed velocity; scanning techniques; ultrasonic scanners; vascular diseases; Apertures; Blood flow; Doppler measurements; Hardware; Image reconstruction; In vivo; Probes; Real time systems; Ultrasonic variables measurement; Vectors; Clinical environment; Doppler measurements; Real-Time systems; Two-dimensional; Vector Doppler; real-time systems; two-dimensional (2-D); vector Doppler; Biomedical Research; Computer Systems; Echocardiography, Doppler; Equipment Design; Equipment Failure Analysis; Image Enhancement; Image Interpretation, Computer-Assisted; Reproducibility of Results; Sensitivity and Specificity;
fLanguage :
English
Journal_Title :
Medical Imaging, IEEE Transactions on
Publisher :
ieee
ISSN :
0278-0062
Type :
jour
DOI :
10.1109/TMI.2008.927337
Filename :
4556620
Link To Document :
بازگشت