DocumentCode :
778535
Title :
Application of In-Core Detectors to the Startup of Large Boiling Water Reactors
Author :
DuBridge, R.A. ; Neissel, J.P. ; Boyd, L.R.
Author_Institution :
Atomic Power Equipment Department General Electric Company San Jose, California
Volume :
13
Issue :
1
fYear :
1966
Firstpage :
438
Lastpage :
442
Abstract :
This paper describes an in-core reactor startup system employing fission counters and fission chambers to cover the range of in-core neutron flux of 105 - 5 × 1012 nv in a gamma field of 2.5 × 107 R/h at 550°F. The system can also be used with out-of-vessel fission counter-chambers where the range of 100 - 1010 nv has been covered.
Keywords :
Cable shielding; Copper; Counting circuits; Detectors; Inductors; Optical fiber cables; Optical fiber polarization; Power cable insulation; Power cables; Temperature distribution;
fLanguage :
English
Journal_Title :
Nuclear Science, IEEE Transactions on
Publisher :
ieee
ISSN :
0018-9499
Type :
jour
DOI :
10.1109/TNS.1966.4323998
Filename :
4323998
Link To Document :
بازگشت