    A Thermal Neutron Image Intensification System

  • Author

    Berger, Harold ; Kraska, I.R. ; Niklas, Wilfrid F. ; Schmidt, Adolph

  • Author_Institution
    Argonne National Laboratory Argonne, Illinois
  • Volume
    13
  • Issue
    2
  • fYear
    1966
  • fDate
    4/1/1966 12:00:00 AM
  • Firstpage
    79
  • Lastpage
    83
  • Abstract
    An image intensifier tube of the vacuum tube type, sensitive to thermal neutrons has been developed and tested. The tube provides a bright visible output signal for an incoming thermal neutron image. Sensitivity, resolution, speed, contrast and relative response to radiation other than thermal neutrons all appear to be adequate for application to neutron imaging studies employing either reactor or non-reactor thermal neutron sources. The above characteristics, and applications of the system, are discussed.
  • Keywords
    Atomic measurements; Electromagnetic wave absorption; Electron tubes; Image intensifiers; Inspection; Neutrons; Optical attenuators; Radio control; Radiography; X-rays;
  • fLanguage
    English
  • Journal_Title
    Nuclear Science, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0018-9499
  • Type

    jour

  • DOI
    10.1109/TNS.1966.4324064
  • Filename