DocumentCode :
779884
Title :
High resolution readout of metal oxide gas sensors using time-to-digital conversion
Author :
Brunsmann, Ulrich ; Tille, T.
Author_Institution :
Fac. of Eng., FH Aschaffenburg-Univ. of Appl. Sci., Aschaffenburg
Volume :
42
Issue :
20
fYear :
2006
fDate :
9/28/2006 12:00:00 AM
Firstpage :
1148
Lastpage :
1149
Abstract :
Time-to-digital conversion is investigated as a new method to record highly sensitive responses of semiconductor gas sensors. The method is evaluated by exposing metal oxide gas sensors to very low carbon monoxide (CO) concentrations. The noise equivalent detection limit is about 0.5 ppb CO
Keywords :
carbon compounds; gas sensors; readout electronics; CO; carbon monoxide concentrations; high resolution read out; metal oxide gas sensors; noise equivalent detection limit; semiconductor gas sensors; time-to-digital conversion;
fLanguage :
English
Journal_Title :
Electronics Letters
Publisher :
iet
ISSN :
0013-5194
Type :
jour
DOI :
10.1049/el:20062546
Filename :
1706026
Link To Document :
بازگشت