• DocumentCode
    780637
  • Title

    A rigorous treatment of self-shielding and covers in neutron spectra determinations

  • Author

    Griffin, Patrick J. ; Kelly, John G Jake

  • Author_Institution
    Sandia Nat. Labs., Albuquerque, NM, USA
  • Volume
    42
  • Issue
    6
  • fYear
    1995
  • fDate
    12/1/1995 12:00:00 AM
  • Firstpage
    1878
  • Lastpage
    1885
  • Abstract
    Most neutron spectrum determination methodologies ignore self-shielding effects in dosimetry foils and treat covers with an exponential attenuation model. This work provides a quantitative analysis of the approximations in this approach. It also provides a methodology for improving the fidelity of the treatment of the dosimetry sensor response to a level consistent with the user´s spectrum characterization approach. A library of correction functions for the energy-dependent sensor response has been compiled that addresses dosimetry foils/configurations in use at the Sandia National Laboratories Radiation Metrology Laboratory
  • Keywords
    dosimetry; foils; neutron detection; neutron spectrometers; shielding; correction functions; covers; dosimetry foil; exponential attenuation model; neutron spectrum determination; self-shielding; sensor response; Attenuation; Dosimetry; Gamma ray detectors; Gold; Laboratories; Libraries; Metrology; Neutrons; Sensor phenomena and characterization; Sensor systems;
  • fLanguage
    English
  • Journal_Title
    Nuclear Science, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0018-9499
  • Type

    jour

  • DOI
    10.1109/23.489230
  • Filename
    489230